Перейти к содержимому
Низкие цены. Оригиналы и переводы — экономьте время и бюджет.

ASTM E3336-22 PDF

Standard Test Method for Physical Integrity Testing of Single-Use Systems

Название (английский):
ASTM E3336-22

Standard Test Method for Physical Integrity Testing of Single-Use Systems

Статус документа:
Действующий
Формат:
Электронный (PDF)
Количество страниц:
15
Дата публикации:
1 февраля 2022 г.
Издание:
E3336
ICS:
11.120.99
Описание (английский):

SIGNIFICANCE AND USE 4.1 The test methods outlined in this standard allow for suppliers and end users of SUSs in (bio)pharmaceutical manufacturing processes to detect a leak and/or confirm the barrier properties of empty, clean, and dry SUSs. Performing integrity testing can be a significant contribution to the overall integrity assurance of SUSs. 4.2 The two types of physical test methods outlined in this standard are: 4.2.1 Section 5, Pressure-Based Test Methods. 4.2.2 Section 6, Tracer Gas-Based Test Methods. Note 3: Other test methods are currently being adapted for robust, reliable, and reproducible testing SUS, for example, Vacuum Decay Test Method as described in Test Method F2338. 4.3 Pressure-based test methods are generally less sensitive compared to tracer gas-based test methods but have a lower complexity and cost. To assist in selecting a method that will fit an application, refer to Table 1 in Practice E3244 for a more detailed comparison of the two methods. 4.4 Both types of test methods can be used to detect leaks of any sizes in a SUS (referred to as leak testing) or confirm the barrier properties of the SUS (referred to as integrity testing). 4.5 To ensure that integrity testing performed on SUSs is effective and accurate, the properties of the SUS (pressure capabilities, volume, material properties, etc.) must be considered. Also, a validation should be performed on the chosen test method as further described in 5.11 and 6.11. 4.6 Practice E3244 should be referenced to determine the maximum allowable leakage limit for a SUS, along with the routine testing requirements that are suitable for each application. 4.7 The purpose of the described test methods is not to stress the SUS until a potential defect occurs. The testing parameters, mainly test pressure, are independent from the use-case conditions. The robustness of the SUS under use-case conditions should be proven during product qualification. 4.8 This standard test method describes the... SCOPE 1.1 The test methods described in this standard are applicable for single-use manufacturing equipment, further called Single-use Systems (SUSs), used for (bio)pharmaceutical products. 1.2 The test methods described in this standard are not intended to be used on single-use technology for primary containers, combination products (products composed of any combination of a drug, device, or biological product), or devices. Appropriate procedures related to these products are discussed in documents covering the integrity assurance for primary containers (1)2 or medical products (2-4). 1.3 The test methods and their validation are described to only cover testing of empty and dry SUSs. Residual liquid in the SUS can impact the test reliability and reproducibility. 1.4 The test methods are intended to be used to confirm the barrier properties of the test article, further called integrity testing, or test the SUS for leaks of certain sizes, further called leak testing. Note 1: To verify that an integrity test can confirm the intended barrier properties of the SUS, its detection limit must be equal or better than the respective maximum allowable leakage limit. 1.5 The physical test methods covered by this standard are: 1.5.1 Pressure-based test methods. 1.5.2 Tracer gas-based test methods. 1.6 The physical test methods described are in general non-destructive and allow further use of the SUS. Note 2: Some variations can be used in a destructive way, for example, to perform root cause analysis of the leak. 1.7 The standard describes the test apparatuses, operation procedures, environment requirements, and discusses specific challenges with testing SUSs, as well as how to perform robust validation of the test method. 1.8 This standard does not include methods to determine the maximum allowable leakage limit for maintaining the barrier properties of the SUS. For that, refer to Practice E3244 and Test Me...

Технические детали

Технический комитет
E55 - Manufacture of Pharmaceutical and Biopharmaceutical Products
SKU
ASTM E3336-22