Original standard DIN 48207-2 2005-06 in PDF full version. Additional info + preview on request
Full title and description
Overhead lines with nominal voltages exceeding 1 kV — Methods and equipment for the installation of conductors — Part 2: Cable grips (Freileitungen mit Nennspannungen über 1 kV - Verfahren und Ausrüstung zum Verlegen von Leitern - Teil 2: Ziehstrümpfe aus Stahl). This part specifies requirements, design and test guidance for steel cable grips used when stringing conductors on overhead power lines.
Abstract
DIN 48207-2:2005-06 defines the purpose, constructional characteristics and minimum performance requirements for steel braided cable grips (Ziehstrümpfe) intended for use when installing conductors on overhead lines above 1 kV. The document covers mechanical strength, recommended handling and testing principles to ensure safe conductor pulling and transfer of tensile loads during installation.
General information
- Status: Superseded / updated — the 2005 edition has been followed by a revised edition in the DIN/E‑DIN series (E DIN 48207-2:2024-01).
- Publication date: 2005-06 (DIN 48207-2:2005-06; published 1 June 2005).
- Publisher: Deutsches Institut für Normung (DIN).
- ICS / categories: 29.240.20 — Power transmission and distribution lines.
- Edition / version: DIN 48207-2:2005-06 (Part 2 of the DIN 48207 series).
- Number of pages: 7 pages (2005 edition).
Scope
The standard applies to steel braided cable grips used for the installation (stringing and pulling-in) of conductors on overhead power lines with nominal voltages exceeding 1 kV. It addresses mechanical design, dimensions and ranges (working diameters), required tensile performance and test criteria so grips will reliably transfer pulling loads without damaging conductors. The document is intended to be used together with the relevant overhead-line standards (for example the EN/DIN EN series for overhead line construction).
Key topics and requirements
- Definition and classification of steel cable grips for overhead-line conductor installation.
- Design and construction requirements (braid geometry, eyes/loops, ferrules and material considerations for steel grips).
- Nominal/working diameter ranges and matching to conductor sizes.
- Mechanical performance requirements: tensile/pulling force capability and minimum breaking strength tests (requirements for proof or type testing and acceptance criteria).
- Marking, documentation and handling guidance to ensure safe use during stringing operations.
- Testing methods and inspection requirements to verify conformity before field use.
Typical use and users
Primary users are transmission and distribution utilities, overhead-line construction and stringing contractors, manufacturers and suppliers of cable grips and pulling equipment, testing laboratories and safety/inspection personnel involved in overhead-line installation projects. The standard is used to specify procurement requirements, verify product conformity and guide safe installation practice.
Related standards
Commonly referenced documents include standards for overhead line design and installation (e.g. DIN EN 50341 series / VDE: overhead-line design and construction), related parts of the DIN 48207 series (other parts covering connectors and handling equipment) and product-specific standards for conductors and fittings. The 2024 revision of Part 2 aligns references and test language with the current EN/VDE framework.
Keywords
DIN 48207-2, cable grips, cable stockings, cable socks, Ziehstrümpfe, overhead lines, conductor stringing, pulling grips, breaking load, testing, installation equipment, power transmission, 1 kV+
FAQ
Q: What is this standard?
A: DIN 48207-2:2005-06 is the part of the DIN 48207 series that specifies requirements for steel cable grips used to pull or string conductors on overhead power lines with nominal voltages above 1 kV.
Q: What does it cover?
A: It covers the definition, constructional features, mechanical performance (pulling/tensile capability and tests), working diameter ranges, marking and handling guidance for steel braided cable grips used in overhead-line installation.
Q: Who typically uses it?
A: Utilities, line construction contractors, grip and hardware manufacturers, procurement/specification engineers and test laboratories use this standard to specify, supply and verify cable grips for overhead-line work.
Q: Is it current or superseded?
A: The 2005-06 edition has been followed by a revised edition in the DIN/E‑DIN series (E DIN 48207-2:2024-01), so users should refer to the 2024 edition for the latest normative requirements and updated test/terminology.
Q: Is it part of a series?
A: Yes — DIN 48207 is a series covering methods and equipment for the installation of conductors on overhead lines; Part 2 addresses cable grips while other parts cover related fittings and installation equipment.
Q: What are the key keywords?
A: Cable grips, cable stockings, Ziehstrümpfe, overhead-line installation, conductor pulling, tensile strength, breaking load, testing, DIN 48207, power transmission lines.