DIN 6868-150 2022-01 PDF
Name in English:
STB DIN 6868-150 2022-01
Name in Russian:
STB DIN 6868-150 2022-01
Original standard DIN 6868-150 2022-01 in PDF full version. Additional info + preview on request
Full title and description
STB DIN 6868-150: Image quality assurance in diagnostic X‑ray departments — Part 150: Acceptance test of medical radiographic and fluoroscopic X‑ray equipment. The standard specifies procedures and measurable acceptance criteria for verifying image quality, beam geometry, and related performance parameters of radiographic and fluoroscopic systems used in medical diagnostics.
Abstract
This part of DIN 6868 defines the acceptance-test methods, test objects and measurement procedures used to assess radiographic and fluoroscopic X‑ray equipment (including digital subtraction angiography and certain digital volume tomography configurations). It covers image quality checks (spatial resolution, contrast, homogeneity), beam/field alignment and size, dynamic range, and relevant dose/beam quality measurements required at installation or following major modifications.
General information
- Status: Current.
- Publication date: 2022-01 (Edition: 2022-01).
- Publisher: Deutsches Institut für Normung (DIN).
- ICS / categories: 11.040.50 (Radiographic equipment); 37.040.25 (Radiographic films).
- Edition / version: 2022-01 (replaces DIN 6868-150:2013-06).
- Number of pages: 76.
Scope
This standard applies to acceptance testing of medical X‑ray equipment for projection radiography and fluoroscopy, including systems used for digital subtraction angiography and certain digital volume tomography configurations with integrated recording. It specifies required test objects (phantoms), measurement setups, performance parameters to be measured, and acceptance criteria intended for initial installation testing and formal handover. The scope excludes routine constancy/QA schedules that follow acceptance, which are addressed in other parts of the DIN 6868 series.
Key topics and requirements
- Mandatory acceptance measurements for image quality: spatial resolution (line‑pair/MTF checks), low‑contrast detectability, and dynamic range evaluation.
- Verification of effective radiation field size, collimation/beam alignment and centring relative to image receptor.
- Homogeneity/uniformity checks of the receptor and imaging chain.
- Procedures for dose and beam quality measurements required for acceptance (using appropriate dosimetry and test phantoms).
- Specification of test phantoms and pattern elements for repeatable assessments (including manufacturer and user guidance for phantom use in acceptance tests).
- Pass/fail criteria and reporting formats for documenting acceptance test results and deviations at installation.
Typical use and users
Primary users are medical physicists, certified radiology equipment inspectors, clinical engineers, hospital technical staff and manufacturers’ field service engineers responsible for installation and formal acceptance of radiography/fluoroscopy systems. Regulatory bodies and accreditation organizations may also reference this document when assessing compliance with national X‑ray regulations and formal acceptance procedures.
Related standards
DIN 6868-150 is part of the DIN 6868 series on image quality assurance in diagnostic X‑ray departments; related parts address dental equipment (e.g. DIN 6868-151) and other modality‑specific acceptance and constancy tests. The standard is aligned with practical test methods referenced in national X‑ray regulations and with international test practice for medical imaging acceptance.
Keywords
Acceptance test, radiography, fluoroscopy, image quality assurance, DIN 6868, radiographic equipment, DSA, digital volume tomography, phantom, spatial resolution, low‑contrast detectability, dose measurement.
FAQ
Q: What is this standard?
A: DIN 6868-150:2022-01 is the DIN standard that defines acceptance test procedures and measurable criteria for medical radiographic and fluoroscopic X‑ray equipment used in diagnostic radiology.
Q: What does it cover?
A: It covers the procedures, test objects (phantoms), measurement setups and acceptance criteria needed at installation to verify image quality (resolution, contrast, uniformity), beam geometry and certain dose/beam quality parameters for projection radiography and fluoroscopy systems (including DSA and some DVT configurations).
Q: Who typically uses it?
A: Medical physicists, hospital clinical engineers, equipment manufacturers’ service personnel and authorized inspectors conducting formal acceptance testing of X‑ray imaging systems.
Q: Is it current or superseded?
A: Current — the 2022-01 edition is the active edition and replaces the prior published version from 2013.
Q: Is it part of a series?
A: Yes — it is part of the DIN 6868 series on image quality assurance for diagnostic X‑ray departments; related parts (for example DIN 6868‑151 for dental radiography) provide modality‑specific acceptance and testing guidance.
Q: What are the key keywords?
A: Acceptance test, image quality, radiography, fluoroscopy, phantom, dose measurement, DIN 6868, DSA, digital volume tomography.