ASTM F2997-21 PDF

Standard Practice for Quantification of Calcium Deposits in Osteogenic Culture of Progenitor Cells Using Fluorescent Image Analysis

Название (английский):
ASTM F2997-21

Standard Practice for Quantification of Calcium Deposits in Osteogenic Culture of Progenitor Cells Using Fluorescent Image Analysis

Статус документа:
Действующий
Формат:
Электронный (PDF)
Количество страниц:
17
Дата публикации:
15 июня 2021 г.
Издание:
F2997
ICS:
07.100.10
Описание (английский):

SIGNIFICANCE AND USE 5.1 In-vitro osteoblast differentiation assays are one approach to screen progenitor stem cells for their capability to become osteoblasts. The extent of calcium deposits or mineralized matrix that form in vitro may be an indicator of differentiation to a functional osteoblast; however, expression of osteogenic genes or proteins is another important measurement to use in conjunction with this assay to determine the presence of an osteoblast. 5.2 This practice provides a technique for staining, imaging, and quantifying the fluorescence intensity and area related to the mineralization in living cell cultures using the non-toxic calcium-chelating dye, XO. The positively stained area of mineralized deposits in cell cultures is an indirect measure of calcium content. It is important to measure the intensity to ensure that the images have not been underexposed or overexposed. Intensity and area do not correlate directly to calcium content. 5.3 XO enables the monitoring of calcium deposits repeatedly throughout the life of the culture without detriment to the culture. There is no interference on subsequent measurements of the mineralized area due to dye accumulation from repeated application (1).3 Calcium deposits that have been previously stained may appear brighter, but this does not impact the area measurement. Calcein dyes may also be used for this purpose (1) but require a different procedure for analysis than XO (that is, concentration and filter sets) and are thus not included here. Alizarin Red and Von Kossa are not suitable for use with this procedure on living cultures since there is no documentation supporting their repeated use in living cultures without deleterious effects. 5.4 The practice may be applied to cultures of any cells capable of producing calcium deposits. It may also be used to document the absence of mineral in cultures where the goal is to avoid mineralization. 5.5 During osteoblast differentiation assays, osteogenic supplements are ... SCOPE 1.1 This practice defines a method for the estimation of calcium content at multiple time points in living cell cultures that have been cultured under conditions known to promote mineralization. The practice involves applying a fluorescent calcium-chelating dye that binds to the calcium phosphate mineral crystals present in the live cultures followed by image analysis of fluorescence microscopy images of the stained cell cultures. Quantification of the positively stained areas provides a relative measure of the calcium content in the cell culture plate. A precise correlation between the image analysis parameters and calcium content is beyond the scope of this practice. 1.2 Calcium deposition in a secreted matrix is one of several features that characterize bone formation (in vitro and in vivo), and is therefore a parameter that may indicate bone formation and osteoblast function (that is, osteoblastic differentiation). Calcium deposition may, however, be unrelated to osteoblast differentiation status if extensive cell death occurs in the cell cultures or if high amounts of osteogenic medium components that lead to artifactual calcium-based precipitates are used. Distinguishing between calcium deposition associated with osteoblast-produced mineralized matrix and that from pathological or artifactual deposition requires additional structural and chemical characterization of the mineralized matrix and biological characterization of the cell that is beyond the scope of this practice. 1.3 The parameters obtained by image analysis are expressed in relative fluorescence units or area percentage (area%), for example, fraction of coverage of the area analyzed. 1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibili...

Технические детали

Технический комитет
F04 - Medical and Surgical Materials and Devices
SKU
ASTM F2997-21