1 Scope
This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus , which is intended for connection to intrinsically safe circuits which enter such atmospheres.
This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion in the surrounding explosive atmospheres.
This standard is also applicable to electrical equipment or parts of electrical equipment
located outside the explosive atmosphere or protected by another Type of Protection
listed in IEC 60079‑0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical
equipment or parts of such electrical equipment. The electrical circuits exposed to
the explosive atmosphere are evaluated for use in such an atmosphere by applying this standard.
The requirements for intrinsically safe systems are provided in IEC 60079‑25.
This standard supplements and modifies the general requirements of IEC 60079‑0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079‑0, the requirements of this standard shall take precedence.
If requirements in this standard are applicable to both