1 Scope
This part of IEC 60079 specifies requirements for the construction, testing and marking for Group II electrical
equipment with type of protection, "n" intended for use in explosive gas atmospheres.
This standard applies to electrical equipment where the rated voltage does not exceed
15 kV r.m.s. a.c. or d.c.
This part of IEC 60079 is applicable to non-sparking electrical equipment and also to electrical equipment
with parts or circuits producing arcs or sparks or having hot surfaces which, if not
protected in one of the ways specified in this standard, could be capable of igniting
a surrounding explosive gas atmosphere. This standard describes several different
methods by which this can be achieved which may be combined with other methods described
in IEC 60079‑0.
This standard supplements and modifies the general requirements of IEC 60079‑0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079‑0, the requirement of this standard takes precedence.
Table 1
—
Relationship of this part to IEC 60079‑0
Clause of IEC 60079‑0