1 Scope
This part of ISO 4499 gives guidelines for the measurement of hardmetal grain size by metallographic techniques
only using optical or electron microscopy. It is intended for sintered WC/Co hardmetals
(also called cemented carbides or cermets) containing primarily WC as the hard phase.
It is also intended for measuring the grain size and distribution by the linear-intercept
technique.
This part of ISO 4499 essentially covers four main topics:
— calibration of microscopes, to underpin the accuracy of measurements;
— linear analysis techniques, to acquire sufficient statistically meaningful data;
— an alysis methods, to calculate representative average values;
— reporting, to comply with modern quality requirements.
The part of ISO 4499 is supported by a measurement case study to illustrate the recommended techniques
(see Annex A ).
The part of ISO 4499 is not intended for the following.
— Measurements of size distribution.
— Recommendations on shape measurements. Further research is needed before recommendations
...