ASTM C1644/C1644M-24 PDF

St ASTM C1644/C1644M-24

Name in English:
St ASTM C1644/C1644M-24

Name in Russian:
Ст ASTM C1644/C1644M-24

Description in English:

Original standard ASTM C1644/C1644M-24 in PDF full version. Additional info + preview on request

Description in Russian:
Оригинальный стандарт ASTM C1644/C1644M-24 в PDF полная версия. Дополнительная инфо + превью по запросу
Document status:
Active

Format:
Electronic (PDF)

Delivery time (for English version):
1 business day

Delivery time (for Russian version):
200 business days

SKU:
stastm02679

Choose Document Language:
€15

Full title and description

Standard Specification for Resilient Connectors Between Reinforced Concrete On‑Site Wastewater Tanks and Pipes — ASTM C1644/C1644M-24. This specification establishes minimum material and performance requirements and required test procedures for resilient connectors used to join reinforced concrete on‑site wastewater (septic) tanks to piping systems to prevent leakage and accommodate movement.

Abstract

This specification covers material, design, and performance requirements for resilient connectors used at connections between reinforced concrete on‑site wastewater tanks and pipes. All materials are required to be suitable for sanitary sewage service. Each connector design must be tested for straight alignment, axial deflection, and shear loading, and meet specified acceptance criteria. Test provisions address hydrostatic performance up to 5 psi (11.5 ft) and both SI and inch‑pound unit systems are permitted independently.

General information

  • Status: Active
  • Publication date: January 11, 2024 (current edition C1644/C1644M-24; last updated December 13, 2024)
  • Publisher: ASTM International
  • ICS / categories: 23.040.60 (Flanges, couplings and joints) — related to water/wastewater containment and connections
  • Edition / version: C1644/C1644M-24
  • Number of pages: 5

Scope

The standard specifies minimum performance and material requirements for resilient connectors intended for connections between reinforced concrete on‑site wastewater tanks and pipes (including connectors used with structures covered by Specifications C913 and C1227). The scope is limited to the resilient connection itself and its performance under straight alignment, axial deflection, and shear loading tests; it does not address all factors affecting installed system infiltration/exfiltration beyond the connector. The specification permits use of either SI or inch‑pound units (treated independently).

Key topics and requirements

  • Material suitability for sanitary sewage service (chemical and environmental resistance).
  • Minimum performance criteria for leakage and mechanical behaviour.
  • Required test methods: straight alignment, axial deflection, and shear loading.
  • Hydrostatic performance provisions (tested for leakage at pressures up to 5 psi / ~11.5 ft head).
  • Design, marking, and product acceptance criteria for connector types.
  • Separate, non‑interchangeable use of SI and inch‑pound units to avoid non‑conformance.

Typical use and users

Used by manufacturers of resilient connectors and seals, precast concrete septic tank and grease interceptor producers, civil and wastewater engineers, product testing laboratories, specification writers, and regulatory bodies overseeing on‑site wastewater systems. Typical applications include sealing inlet/outlet pipe penetrations in reinforced concrete septic tanks and other on‑site wastewater structures to prevent leakage while accommodating movement.

Related standards

Referenced and related standards include ASTM C913 (Precast Concrete Water and Wastewater Structures), ASTM C1227 (Precast Concrete Septic Tanks), and several elastomer/material test methods and specifications that address chemical resistance and rubber properties (for example ASTM test methods referenced within the specification). Additional related ASTM standards on joint materials and seal testing are commonly used in conjunction with C1644/C1644M.

Keywords

resilient connector; septic tank connector; reinforced concrete tanks; on‑site wastewater; pipe connection; leakage; axial deflection; shear loading; hydrostatic test; ASTM C1644; sanitary sewage materials.

FAQ

Q: What is this standard?

A: ASTM C1644/C1644M-24 is a specification that defines minimum material and performance requirements and required test methods for resilient connectors used between reinforced concrete on‑site wastewater tanks and pipes.

Q: What does it cover?

A: It covers the resilient connection itself — required materials, performance criteria, and test procedures (straight alignment, axial deflection, shear loading) to demonstrate acceptable leakage and mechanical performance under specified conditions, including hydrostatic testing up to 5 psi.

Q: Who typically uses it?

A: Manufacturers of connectors and precast concrete tanks, civil/wastewater engineers, testing laboratories, specifiers, and regulators involved with on‑site wastewater systems and product certification.

Q: Is it current or superseded?

A: The C1644/C1644M-24 edition is the current, active edition (publication January 11, 2024; noted update December 13, 2024). Users should confirm they are using the latest edition when preparing specifications or performing tests.

Q: Is it part of a series?

A: It is maintained under ASTM Committee C27 (Precast Concrete Products), Subcommittee C27.30, and is related to other ASTM specifications for precast concrete wastewater structures and seal/joint materials (for example C913 and C1227).

Q: What are the key keywords?

A: Resilient connector, septic tank, reinforced concrete, wastewater, pipe connection, leakage, axial deflection, shear loading, hydrostatic test, sanitary sewage materials.