Перейти к содержимому
Low prices. Originals and translations — save time and budget.

EN ISO 80601-2-13:2012 PDF

Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation (ISO 80601-2-13:2011)

Title (English):
EN ISO 80601-2-13:2012

Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation (ISO 80601-2-13:2011)

Document status:
Withdrawn
Format:
Electronic (PDF)
Number of pages:
114
Publication date:
December 12, 2012
Edition:
CEN EN 80601 edition 2 version 1
ICS:
11.040.10
Description (English):

ISO/IEC 80601-2-13:2011 is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator. ISO/IEC 80601-2-13:2011 specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification: anaesthetic gas delivery system; anaesthetic breathing system; anaesthetic gas scavenging system; anaesthetic vapour delivery system; anaesthetic ventilator; monitoring equipment; alarm system; protection device. ISO/IEC 80601-2-13:2011 is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation. If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components, as relevant. Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components within the scope of ISO/IEC 80601-2-13:2011 are not covered by specific requirements in ISO/IEC 80601-2-13:2011 except in 7.2.13 and 8.4.1 of IEC 60601-1:2005. ISO/IEC 80601-2-13:2011 is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB.

Technical details

Technical committee
CEN/TC 215 - Respiratory and anaesthetic equipment
SKU
EN ISO 80601-2-13:2012