1 Scope and object
This Technical Specification is applicable to industrial electroheating installations
using electric energy as input, alone or in combination with other kinds of energy.
However, external combustible fuel energy input is not dealt with, and all considerations
begin at the electric only mains frequency source to which the installation is connected.
Any external voltage transformation from the supply network to the plant into a special
voltage which is fed into the installation is not dealt with in this Technical Specification,
since it is not considered a responsibility of the manufacturer of the installation.
The object of this Technical Specification is to provide methods for determination
of the efficiency of a given system as well as enabling comparisons with other equipment
using the same principle for processing of the workload.
For satisfactory comparisons to be possible, differences in end product quality and influences of environmental factors on heat recovery are included.
Heat recovery aspects are dealt with but limited to the temperature changes, the specific
heat capacity characteristics, and the physical properties of the usually fluidic
substance obtained from the installation and employed for energy recovery use. Conversion
into mechanical energy is dealt with.
Adaptation to the needs of operation and performance management as might be necessary
for the implementation or application of smart grid technologies, is addressed but
no test methods are given.
A guideline is provided for the development of the detailed electroheating efficiency
tests for th...