1 Scope
This document specifies methods for determining the uncertainty of the measurement and evaluation of human exposure to vibration. It applies to measurements
of vibration quantities ( measurands ), calculated following a relevant measurement model on the basis of directly measured
values, to evaluate
a) human exposure to hand-transmitted vibration at the workplace,
b) vibration emission of hand-held and hand-guided machinery in a laboratory setting,
c) human exposure to whole-body vibration at the workplace, and
d) whole-body vibration emission of vehicles.
Examples of the application of the individual methods in practical situations are
provided in the annexes.
In this document a measurement error is defined as the difference between a measured
and a reference quantity value.
In this document “ uncertainty ” does not include errors that result from bad measurement strategies, faulty use
of measurement equipment or other mistakes.