Overview
EN ISO 9073-11:2004 - Textiles: Test methods for nonwovens - Part 11: Run-off defines a laboratory run-off test to measure the quantity of liquid (simulated urine) that runs off a nonwoven test piece placed on an inclined plane and superimposed on a standard absorbent medium. The method is intended to compare run-off performance of nonwovens (not to simulate in-use conditions of finished hygiene products). Three alternative procedures are specified: Test I (basic for hydrophilic nonwovens), Test II (repeated-test for performance consistency), and Test III (modified inclination for hydrophobic nonwovens).
Key topics and requirements
- Test principle: A specified mass of simulated urine is dispensed onto a nonwoven sample on a standard absorbent media on an inclined run-off table; excess liquid is collected by a receiver pad and weighed to determine run-off.
- Test liquid: Simulated urine - 9 g/L sodium chloride in grade 3 water, surface tension ≈ 70 ± 2 mN/m at 20 ± 2 °C.
- Typical test parameters:
- Dose: 25.0 g ± 0.5 g delivered in 4.0 s ± 0.1 s (via a 5 mm internal diameter tube).
- Table inclination: nominally 25° (Test I); Test III specifies a different inclination for hydrophobic materials.
- Sample size and orientation: cut pieces (e.g., 140 × 280 mm) with the longer side in machine direction; minimum number of replicates (typically 5).
- Standard absorbent medium: two layers of reference filter paper with defined mass per unit area and absorptive properties (specified tolerances).
- Results and reporting:
- Run-off (grams) per specimen = mass after test − mass before test.
- Average run-off, standard deviation, and optionally percent run-off (relative to delivered dose) are reported.
- Test report should reference EN ISO 9073-11 and document material type, individual results and any deviations.
Applications and users
- Useful for nonwoven manufacturers, R&D teams, and laboratory test houses evaluating liquid management behavior of nonwovens used in hygiene products (diapers, feminine care, incontinence pads), medical disposables, filtration overlays and other absorbent systems.
- Supports quality control, product benchmarking, formulation or layer-structure optimization, and supplier comparisons where run-off resistance is a performance criterion.
- Not a direct predictor of consumer in-use behavior; best used alongside other tests (strike-through, absorption, demand absorbency) for a fuller liquid handling profile.
Related standards
- ISO 9073 series (other parts): Part 6 - Absorption (ISO 9073-6), Part 8 - Liquid strike-through time (ISO 9073-8), Part 12 - Demand absorbency.
- Conditioning and reference documents: ISO 139 (standard atmospheres), ISO 3696 (water for laboratory use), ISO 186 (sampling).
Keywords: EN ISO 9073-11:2004, run-off test, nonwovens, simulated urine, absorbent media, hydrophilic, hydrophobic, textiles test methods, liquid management.