Overview
IEC 60071-2, "Insulation co‑ordination - Part 2: Application guide" (3rd ed., 1996) is an application guide that supports IEC 60071-1 for the selection and justification of rated withstand voltages for three‑phase electrical systems with nominal voltages above 1 kV. It explains how to associate the required insulation levels with the standardized highest voltages for equipment (Ranges I and II), and serves as a horizontal guidance document (IEC Guide 108). The guide focuses on insulation coordination for phase‑to‑earth, phase‑to‑phase and longitudinal insulation and outlines procedures for determining representative service stresses and required testing levels.
Key topics
- Representative voltage stresses in service: origin, classification and representative overvoltages (lightning, switching, slow‑front, transferred).
- Coordination withstand voltage: insulation strength characteristics, performance criteria and co‑ordination procedures.
- Required withstand voltage: atmospheric corrections, safety factors and statistical considerations.
- Standard withstand voltages and test procedures: conversion factors and type‑test correlations.
- Special considerations: detailed guidance for overhead lines (lightning, switching, line energization) and substations (layout, transferred overvoltages).
- Annexes and examples: air clearances, temporary overvoltages from earth faults, Weibull statistics, transformer transferred voltages, lightning, gap factors and worked insulation‑coordination examples.
Applications
IEC 60071-2 is a practical guide for:
- Determining rated impulse and power‑frequency withstand voltages for equipment and installations.
- Selecting and applying surge arresters, specifying lead lengths and connection practices.
- Defining minimum air‑clearances and creepage distances to meet specified impulse withstand voltages.
- Evaluating the risk of flashover or dielectric failure under realistic service overvoltages (lightning, switching, earth faults).
- Supporting design and specification of substations, overhead transmission lines and high‑voltage equipment operating above 1 kV.
Who should use this standard
- Electrical design engineers and system planners in utilities and industry
- Substation and transmission line designers
- Manufacturers of switchgear, transformers and surge arresters
- Test laboratories and product committees establishing dielectric tests
- Standards bodies and consultants working on insulation coordination
Related standards
Important normative references include:
- IEC 60071-1 (Definitions, principles and rules)
- IEC 60‑1 (High‑voltage test techniques)
- IEC 99 series (surge arresters)
- IEC 56 (circuit‑breakers), IEC 507/815 (insulators/pollution)
Keywords: IEC 60071-2, insulation coordination, withstand voltage, overvoltages, surge arrester, phase-to-earth, phase-to-phase, substations, overhead lines.